Product Overview
Product Description
This listing is for a used horizontal ASME pressure vessel removed from the Huerfano Mountain Gas Plant in New Mexico. The vessel is offered for sale in as-removed condition and may be suitable for refurbishment, repurposing, or return to service following inspection and any work required by the purchaser's application.
The vessel is approximately 82 feet long by 8 feet in diameter, with an estimated capacity of approximately 30,000 gallons. Based on the National Board registration, the vessel was manufactured in 1980 for Cyprus Arizona and is registered under National Board Number 190.
At the time of dismantling, this vessel was not in active process service. Its original application within the facility is unknown.
The vessel is mounted on heavy structural support rails and includes multiple process nozzles and internal piping visible through the manway opening. This heavy-wall ASME pressure vessel may be suitable for continued industrial service, refurbishment, storage, or repurposing, subject to inspection and engineering evaluation by the purchaser.
Equipment Features
- Horizontal ASME pressure vessel
- Approximately 82 feet long
- Approximately 8 feet outside diameter
- Estimated capacity approximately 30,000 gallons
- Manufactured circa 1980
- National Board Registration No. 190
- MAWP 350 PSI
- ASME STAMP U
- RT-2
- Originally manufactured for Cyprus Arizona
- Mounted on structural support rails
- Multiple process nozzles
- Internal piping visible through manway
- Heavy-duty industrial construction
- Available for inspection at the Hess Services yard
Typical Applications
Large ASME pressure vessels are commonly utilized for applications such as:
- Hydrocarbon storage
- Process surge service
- Separator service
- Liquid accumulation
- Industrial process systems
- Custom process equipment
- Repurposed industrial storage
Actual suitability for any application should be determined by the purchaser and their engineering personnel.
Condition
This equipment was removed from service during the dismantling of the former Elm Ridge 300 BPD Condensate Stabilization Facility. The vessel was not in active service at the time of dismantling and is being offered in its current as-removed condition.
Inspection is encouraged prior to purchase.
Additional Services Available
Hess Services may be able to provide:
- Equipment inspection
- Refurbishment and repair
- Pressure testing and recertification (where applicable)
- Painting and coating
- Non-destructive examination (NDE)
- Loading assistance
- Transportation coordination
Please contact us to discuss your project requirements.
Inspection & Sales Information
Additional photographs, measurements, and available documentation can be provided upon request.
Equipment is offered subject to prior sale.